Picosecond electrical characterization of x-ray microchannel-plate detectors used in diagnosing inertial confinement fusion experiments
Denysenko, A. ; Alexandrou, S. ; Wang, C.-C. ; Bradley, D. K. ; Donaldson, W. R. ; Hsiang, T. Y. ; Sobolewski, Roman ; Bell, P. M.
[S.l.] : American Institute of Physics (AIP)
Published 1993
[S.l.] : American Institute of Physics (AIP)
Published 1993
ISSN: |
1089-7623
|
---|---|
Source: |
AIP Digital Archive
|
Topics: |
Physics
Electrical Engineering, Measurement and Control Technology
|
Notes: |
The picosecond electrical pulse-propagation characteristics of microchannel-plate detectors, used in diagnosing laser-driven inertial-confinement-fusion experiments, were measured with an electro-optic sampling system. We determined propagation velocity and signal distortion of the microchannel-plate microstrip, as well as its characteristic impedance and the substrate relative dielectric permittivity. These parameters are critical for proper calibration of the detectors and serve as a guide for their improved designs.
|