Transient measurement of dissolved oxygen using membrane electrodes
ISSN: |
0265-928X
|
---|---|
Keywords: |
computer aided measurement. ; diffusion-reaction model ; fouling ; oxygen sensor ; transient mode measurement
|
Source: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
|
Topics: |
Biology
Electrical Engineering, Measurement and Control Technology
Physics
|
Type of Medium: |
Electronic Resource
|
URL: |
_version_ | 1798291735049142272 |
---|---|
autor | Wang, H.Y. Li, X.-M. |
autorsonst | Wang, H.Y. Li, X.-M. |
book_url | http://dx.doi.org/10.1016/0265-928X(89)80009-4 |
datenlieferant | nat_lic_papers |
fussnote | Transient mode dissolved oxygen measurement has been studied using a specially constructed galvanic membrane electrode controlled by a microcomputer. A four-layer diffusion model was developed to describe the dynamic behavior of the electrode. The data interpretation method is based on on-line computer simulation and parameter estimation techniques. A user-friendly computer software package is also developed for calibration and measurement control. Both experimental and theoretical studies indicate that such measurement is less sensitive to fouling and changes in flow conditions than steady state operation of the electrode. |
hauptsatz | hsatz_simple |
identnr | NLZ187978255 |
issn | 0265-928X |
journal_name | Biosensors |
materialart | 1 |
package_name | Elsevier |
publikationsort | Amsterdam |
publisher | Elsevier |
reference | 4 (1989), S. 273-285 |
schlagwort | computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement |
search_space | articles |
shingle_author_1 | Wang, H.Y. Li, X.-M. |
shingle_author_2 | Wang, H.Y. Li, X.-M. |
shingle_author_3 | Wang, H.Y. Li, X.-M. |
shingle_author_4 | Wang, H.Y. Li, X.-M. |
shingle_catch_all_1 | Wang, H.Y. Li, X.-M. Transient measurement of dissolved oxygen using membrane electrodes computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement 0265-928X 0265928X Elsevier |
shingle_catch_all_2 | Wang, H.Y. Li, X.-M. Transient measurement of dissolved oxygen using membrane electrodes computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement 0265-928X 0265928X Elsevier |
shingle_catch_all_3 | Wang, H.Y. Li, X.-M. Transient measurement of dissolved oxygen using membrane electrodes computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement 0265-928X 0265928X Elsevier |
shingle_catch_all_4 | Wang, H.Y. Li, X.-M. Transient measurement of dissolved oxygen using membrane electrodes computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement computer aided measurement. diffusion-reaction model fouling oxygen sensor transient mode measurement 0265-928X 0265928X Elsevier |
shingle_title_1 | Transient measurement of dissolved oxygen using membrane electrodes |
shingle_title_2 | Transient measurement of dissolved oxygen using membrane electrodes |
shingle_title_3 | Transient measurement of dissolved oxygen using membrane electrodes |
shingle_title_4 | Transient measurement of dissolved oxygen using membrane electrodes |
sigel_instance_filter | dkfz geomar wilbert ipn albert fhp |
source_archive | Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
timestamp | 2024-05-06T08:37:21.110Z |
titel | Transient measurement of dissolved oxygen using membrane electrodes |
titel_suche | Transient measurement of dissolved oxygen using membrane electrodes Transient mode dissolved oxygen measurement has been studied using a specially constructed galvanic membrane electrode controlled by a microcomputer. A four-layer diffusion model was developed to describe the dynamic behavior of the electrode. The data interpretation method is based on on-line computer simulation and parameter estimation techniques. A user-friendly computer software package is also developed for calibration and measurement control. Both experimental and theoretical studies indicate that such measurement is less sensitive to fouling and changes in flow conditions than steady state operation of the electrode. |
topic | W ZN U |
uid | nat_lic_papers_NLZ187978255 |