The sensitive time of a wide gap spark chamber

Eisenstein, B. ; Grossman, D. ; Sah, R. ; Strauch, K.

Amsterdam : Elsevier
ISSN:
0029-554X
Source:
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
Topics:
Energy, Environment Protection, Nuclear Power Engineering
Physics
Type of Medium:
Electronic Resource
URL:
_version_ 1798291154385502208
autor Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
autorsonst Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
book_url http://linkinghub.elsevier.com/retrieve/pii/0029-554X(66)90339-9
datenlieferant nat_lic_papers
fussnote The sensitive time of a typical 40 cm wide gap chamber operated in the spark mode and filled with 90% Ne-10% He at 1.1 atm has been determined using 158 MeV protons. It is found that the efficiency for obtaining good tracks is 〉98% when two or three particles arrive within 0.5 μsec of the application of the high voltage pulse and that this efficiency decreases rapidly with arrival times larger than 0.5 μsec.
hauptsatz hsatz_simple
identnr NLZ180559397
issn 0029-554X
journal_name Nuclear Instruments and Methods
materialart 1
package_name Elsevier
publikationsort Amsterdam
publisher Elsevier
reference 41 (1966), S. 69-72
search_space articles
shingle_author_1 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
shingle_author_2 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
shingle_author_3 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
shingle_author_4 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
shingle_catch_all_1 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
The sensitive time of a wide gap spark chamber
0029-554X
0029554X
Elsevier
shingle_catch_all_2 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
The sensitive time of a wide gap spark chamber
0029-554X
0029554X
Elsevier
shingle_catch_all_3 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
The sensitive time of a wide gap spark chamber
0029-554X
0029554X
Elsevier
shingle_catch_all_4 Eisenstein, B.
Grossman, D.
Sah, R.
Strauch, K.
The sensitive time of a wide gap spark chamber
0029-554X
0029554X
Elsevier
shingle_title_1 The sensitive time of a wide gap spark chamber
shingle_title_2 The sensitive time of a wide gap spark chamber
shingle_title_3 The sensitive time of a wide gap spark chamber
shingle_title_4 The sensitive time of a wide gap spark chamber
sigel_instance_filter dkfz
geomar
wilbert
ipn
albert
fhp
source_archive Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
timestamp 2024-05-06T08:28:06.493Z
titel The sensitive time of a wide gap spark chamber
titel_suche The sensitive time of a wide gap spark chamber
The sensitive time of a typical 40 cm wide gap chamber operated in the spark mode and filled with 90% Ne-10% He at 1.1 atm has been determined using 158 MeV protons. It is found that the efficiency for obtaining good tracks is 〉98% when two or three particles arrive within 0.5 μsec of the application of the high voltage pulse and that this efficiency decreases rapidly with arrival times larger than 0.5 μsec.
topic ZP
U
uid nat_lic_papers_NLZ180559397