Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint

Chen, I.-C. ; Whang, C.-W.

Amsterdam : Elsevier
ISSN:
0021-9673
Source:
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
Topics:
Chemistry and Pharmacology
Type of Medium:
Electronic Resource
URL:
_version_ 1798290924916178944
autor Chen, I.-C.
Whang, C.-W.
autorsonst Chen, I.-C.
Whang, C.-W.
book_url http://linkinghub.elsevier.com/retrieve/pii/0021-9673(93)80133-S
datenlieferant nat_lic_papers
fussnote A system for coupling amperometric detection with capillary electrophoresis (CE) is described. The interface is formed by fracturing the capillary followed by covering the fracture with a thin layer of cellulose acetate (CA) fihn. The porous CA joint enables off-column amperometric detection to be performed without adverse effects from the high electrophoretic voltage. The primary advantage of this CA joint is its simple construction. The performance of the CE-amperometric detection system was evaluated with hydroquinone. A detection limit of 8 . 10^-^8 M or 0.17 fmol with a theoretical plate number exceeding 90 000 was obtained. Application of the system to the separation and detection of aminophenols, catecholamines and catechol was also demonstrated.
hauptsatz hsatz_simple
identnr NLZ174270933
issn 0021-9673
journal_name Journal of Chromatography A
materialart 1
package_name Elsevier
publikationsort Amsterdam
publisher Elsevier
reference 644 (1993), S. 208-212
search_space articles
shingle_author_1 Chen, I.-C.
Whang, C.-W.
shingle_author_2 Chen, I.-C.
Whang, C.-W.
shingle_author_3 Chen, I.-C.
Whang, C.-W.
shingle_author_4 Chen, I.-C.
Whang, C.-W.
shingle_catch_all_1 Chen, I.-C.
Whang, C.-W.
Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
0021-9673
00219673
Elsevier
shingle_catch_all_2 Chen, I.-C.
Whang, C.-W.
Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
0021-9673
00219673
Elsevier
shingle_catch_all_3 Chen, I.-C.
Whang, C.-W.
Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
0021-9673
00219673
Elsevier
shingle_catch_all_4 Chen, I.-C.
Whang, C.-W.
Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
0021-9673
00219673
Elsevier
shingle_title_1 Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
shingle_title_2 Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
shingle_title_3 Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
shingle_title_4 Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
sigel_instance_filter dkfz
geomar
wilbert
ipn
albert
fhp
source_archive Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
timestamp 2024-05-06T08:24:28.449Z
titel Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
titel_suche Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint
A system for coupling amperometric detection with capillary electrophoresis (CE) is described. The interface is formed by fracturing the capillary followed by covering the fracture with a thin layer of cellulose acetate (CA) fihn. The porous CA joint enables off-column amperometric detection to be performed without adverse effects from the high electrophoretic voltage. The primary advantage of this CA joint is its simple construction. The performance of the CE-amperometric detection system was evaluated with hydroquinone. A detection limit of 8 . 10^-^8 M or 0.17 fmol with a theoretical plate number exceeding 90 000 was obtained. Application of the system to the separation and detection of aminophenols, catecholamines and catechol was also demonstrated.
topic V
uid nat_lic_papers_NLZ174270933