The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results
ISSN: |
1573-2630
|
---|---|
Keywords: |
self-tonometry ; non-contact tonometer ; intraocular pressure (IOP) ; glaucoma ; Goldmann tonometer
|
Source: |
Springer Online Journal Archives 1860-2000
|
Topics: |
Medicine
|
Notes: |
Abstract The authors considered the possibility of using the Pulsair-Keeler non-contact tonometer in self-tonometry. For this reason, 45 patients have been trained to use the instrument and, after a reasonable trial period, were able to self-measure their IOP, The results have been compared to the tonometric values measured with Goldmann tonometer to evaluate statistically the limits and the dependability of this method of measurement. The results shows that self-tonometry with the Pulsair-Keeler tonometer can be used in monitoring glaucomatous patients at home.
|
Type of Medium: |
Electronic Resource
|
URL: |
_version_ | 1798296653845757952 |
---|---|
autor | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. |
autorsonst | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. |
book_url | http://dx.doi.org/10.1007/BF00917979 |
datenlieferant | nat_lic_papers |
hauptsatz | hsatz_simple |
identnr | NLM194444368 |
issn | 1573-2630 |
journal_name | International ophthalmology |
materialart | 1 |
notes | Abstract The authors considered the possibility of using the Pulsair-Keeler non-contact tonometer in self-tonometry. For this reason, 45 patients have been trained to use the instrument and, after a reasonable trial period, were able to self-measure their IOP, The results have been compared to the tonometric values measured with Goldmann tonometer to evaluate statistically the limits and the dependability of this method of measurement. The results shows that self-tonometry with the Pulsair-Keeler tonometer can be used in monitoring glaucomatous patients at home. |
package_name | Springer |
publikationsjahr_anzeige | 1992 |
publikationsjahr_facette | 1992 |
publikationsjahr_intervall | 8009:1990-1994 |
publikationsjahr_sort | 1992 |
publisher | Springer |
reference | 16 (1992), S. 295-297 |
schlagwort | self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer |
search_space | articles |
shingle_author_1 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. |
shingle_author_2 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. |
shingle_author_3 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. |
shingle_author_4 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. |
shingle_catch_all_1 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer Abstract The authors considered the possibility of using the Pulsair-Keeler non-contact tonometer in self-tonometry. For this reason, 45 patients have been trained to use the instrument and, after a reasonable trial period, were able to self-measure their IOP, The results have been compared to the tonometric values measured with Goldmann tonometer to evaluate statistically the limits and the dependability of this method of measurement. The results shows that self-tonometry with the Pulsair-Keeler tonometer can be used in monitoring glaucomatous patients at home. 1573-2630 15732630 Springer |
shingle_catch_all_2 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer Abstract The authors considered the possibility of using the Pulsair-Keeler non-contact tonometer in self-tonometry. For this reason, 45 patients have been trained to use the instrument and, after a reasonable trial period, were able to self-measure their IOP, The results have been compared to the tonometric values measured with Goldmann tonometer to evaluate statistically the limits and the dependability of this method of measurement. The results shows that self-tonometry with the Pulsair-Keeler tonometer can be used in monitoring glaucomatous patients at home. 1573-2630 15732630 Springer |
shingle_catch_all_3 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer Abstract The authors considered the possibility of using the Pulsair-Keeler non-contact tonometer in self-tonometry. For this reason, 45 patients have been trained to use the instrument and, after a reasonable trial period, were able to self-measure their IOP, The results have been compared to the tonometric values measured with Goldmann tonometer to evaluate statistically the limits and the dependability of this method of measurement. The results shows that self-tonometry with the Pulsair-Keeler tonometer can be used in monitoring glaucomatous patients at home. 1573-2630 15732630 Springer |
shingle_catch_all_4 | Boles Carenini, B. Brogliatti, B. Tonetto, C. Renis, E. The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer self-tonometry non-contact tonometer intraocular pressure (IOP) glaucoma Goldmann tonometer Abstract The authors considered the possibility of using the Pulsair-Keeler non-contact tonometer in self-tonometry. For this reason, 45 patients have been trained to use the instrument and, after a reasonable trial period, were able to self-measure their IOP, The results have been compared to the tonometric values measured with Goldmann tonometer to evaluate statistically the limits and the dependability of this method of measurement. The results shows that self-tonometry with the Pulsair-Keeler tonometer can be used in monitoring glaucomatous patients at home. 1573-2630 15732630 Springer |
shingle_title_1 | The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results |
shingle_title_2 | The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results |
shingle_title_3 | The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results |
shingle_title_4 | The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results |
sigel_instance_filter | dkfz geomar wilbert ipn albert fhp |
source_archive | Springer Online Journal Archives 1860-2000 |
timestamp | 2024-05-06T09:55:31.938Z |
titel | The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results |
titel_suche | The Pulsair-Keeler non-contact tonometer in self-tonometry: preliminary results |
topic | WW-YZ |
uid | nat_lic_papers_NLM194444368 |