High-sensitivity absorption measurement in water and glass samples using a mode-mismatched pump-probe thermal lens method
Marcano O., A. ; Loper, C. ; Melikechi, N.
Woodbury, NY : American Institute of Physics (AIP)
Published 2001
Woodbury, NY : American Institute of Physics (AIP)
Published 2001
ISSN: |
1077-3118
|
---|---|
Source: |
AIP Digital Archive
|
Topics: |
Physics
|
Notes: |
We report on a mode-mismatched pump-probe thermal lens experiment performed to measure absorption coefficients as small as 10−8 cm−1 in liquid and solid samples. We take advantage of the large axial dimension of the thermal lens by focusing the pump beam in the presence of a collimated probe beam. We measure an absorption coefficient at 533 nm of (6.8±0.1)×10−4 cm−1 and of (3±0.3)×10−6 cm−1 for distilled water and BK7 optical glass, respectively. © 2001 American Institute of Physics.
|
Type of Medium: |
Electronic Resource
|